{"id":127,"date":"2015-05-26T16:01:03","date_gmt":"2015-05-26T07:01:03","guid":{"rendered":"http:\/\/www.lexi.co.jp\/?page_id=127"},"modified":"2021-12-24T16:43:22","modified_gmt":"2021-12-24T07:43:22","slug":"zedhip","status":"publish","type":"page","link":"http:\/\/www.lexi.co.jp\/en\/products\/zedview\/zedhip","title":{"rendered":"ZedHip"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2369 size-full\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/02.ZedHip_en.png\" alt=\"\" width=\"1536\" height=\"622\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/02.ZedHip_en.png 1536w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/02.ZedHip_en-768x311.png 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/p>\n            <div class=\"ui modal\">\r\n                <div class=\"header\">\r\n                    Notice\r\n                <\/div>\r\n                <div class=\"content\">\r\n                    <div class=\"description\">\r\n                        <p>\r\n                            The pages you are about to visit include information on a \"professional use only\" medical device.  It is not intended for general distribution.  Are you a medical professional?\r\n                        <\/p>\r\n                    <\/div>\r\n                <\/div>\r\n                <div class=\"actions\">\r\n                    <div class=\"ui black deny button\">\r\n                        No\r\n                    <\/div>\r\n                    <div class=\"ui positive right labeled icon button\">\r\n                        Yes\r\n                        <i class=\"checkmark icon\"><\/i>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n\r\n            <script type=\"text\/javascript\">\r\n                jQuery(function ($) {\r\n                    var dlg = $('.ui.modal')\r\n                        .modal('setting', {\r\n                                closable: false,\r\n                                onApprove: function() {\r\n                                    $.cookie('medical_warn_checked', 'true', { expires: 30, path: '\/' });\r\n                                    return true;\r\n                                },\r\n                                onDeny: function() {\r\n                                    location.href=\"\/en\/\";\r\n                                    return true;\r\n                                }\r\n                            }\r\n                        );\r\n                    if($.cookie('medical_warn_checked') === undefined)\r\n                    {\r\n                        dlg.modal('show');\r\n                    }\r\n                });\r\n            <\/script>\n<h1>Overview<\/h1>\n<p>ZedHip creates 3D models of the bone using CT data, and supports planning and assessing THA (Total Hip Arthroplasty).<br \/>\nUser can perform surgical simulations (such as positioning of implants, calculation of parameters, etc.) in simple steps, and also calculate ROM (Range Of Motion) of the hip.<\/p>\n<p><a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2015\/05\/ZedHip_image.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-225\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2015\/05\/ZedHip_image.jpg\" alt=\"\" width=\"300\" height=\"161\" hspace=\"100\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2015\/05\/ZedHip_image.jpg 470w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2015\/05\/ZedHip_image-300x161.jpg 300w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h1>Features<\/h1>\n<h2>Database of Patient Records<\/h2>\n<p>User can import CT data (in DICOM format) into a database application.<br \/>\nPatient information (such as name, sex, date of birth, etc.) can be managed uniformly.<\/p>\n<p><a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2015\/05\/zedhip_db_en.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1877\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_Database.png\" alt=\"\" width=\"512\" height=\"288\" \/><\/a><\/p>\n<h2>Positioning of Implants<\/h2>\n<p>User can select cup and stem from a library of commercially-available implants.<br \/>\nImplants can be placed at optimal positions on 3D model and MPR (multi-planar reconstruction) images.<\/p>\n<p><a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_Implant_2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1878\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_Implant_2.png\" alt=\"\" width=\"512\" height=\"288\" \/><\/a><\/p>\n<h2>Calculation of Parameters<\/h2>\n<p>ZedHip can calculate parameters (such as anteversion, inclination, resection amount, etc.) using reference points and coordinate axes.<br \/>\nResults can be used intra-operatively to perform surgery accurately.<\/p>\n<p><a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_Parameter_2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1879\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_Parameter_2.png\" alt=\"\" width=\"512\" height=\"288\" \/><\/a><\/p>\n<h2>ROM Simulation<\/h2>\n<p>ZedHip can measure ROM of the hip and display the position of impingement.<br \/>\nRisk of post-operative malfunction (such as dislocation) can be reduced.<\/p>\n<p><a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_ROMsimulation.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1880\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/ZedHip_ROMsimulation.png\" alt=\"\" width=\"512\" height=\"288\" \/><\/a><\/p>\n<h2>Post-Operative Assessment (Optional)<\/h2>\n<p>User can compare and assess how implant placement parameters have been changed and placed against the reference plane or reference axis as well as how much the alignment has changed after the operation as compared with pre-operative plans made with ZedHip 3D.<\/p>\n<h1>ZedHip Testimonials<\/h1>\n<div class=\"ui segment\">\n<p><em>\u201cBy using preoperative planning with ZedHip and our simple linked-jig to manage acetabular cup placement, we<br \/>\nhave excellent outcomes on our total hip arthroplasty. We do not place any restrictions on our patients\u2019 daily<br \/>\nactivities after surgery.\u201d<\/em><br \/>\n<strong>Dr. Ito, Tominaga Kusano Hospital, Japan<\/strong><\/p>\n<\/div>\n<div class=\"ui segment\">\n<p><em>\u201cEven for THA experts, I believe ZedHip is very useful not only for difficult cases in revision of femur with<br \/>\nnarrow medullary cavity but also in severely deformed hip as DDH or post osteotomy, Perthes deformity. It is<br \/>\nquite difficult to make an accurate preoperative plan in such a case with a conventional two-dimensional X-ray<br \/>\nbased template software.\u201d<\/em><br \/>\n<strong>Dr. Matsubara, Nissan Tamagawa Hospital, Japan<\/strong><\/p>\n<\/div>\n<div class=\"ui segment\">\n<p><em>\u201cZedHip gives me a very clear and accurate image of surgery for respective patients before my operation. It<br \/>\nprovides quantitative parameters like version, inclination, leg length, head offset change, and etc., all of<br \/>\nthem in 3D! In addition, simulating the range of motion enables me to detect risky impingements among implants<br \/>\nand bones preoperatively and to resect osteophytes during surgery. Finally, it is very easy to use and doesn\u2019t<br \/>\ntake my time.\u201d<\/em><br \/>\n<strong>Dr. Iwakiri, Shiraniwa Hospital Joint Arthroplasty Center, Japan<\/strong><\/p>\n<\/div>\n<div class=\"ui segment\">\n<p><em>\u201cAs 3-Dimensional Templating software, ZedHip is very useful for difficult cases.<br \/>\nIts Range Of Motion simulation function enables us to evaluate impingement of osteophytes around acetabulum. It<br \/>\nshows impingement in 3D image as well as quantitative angles of femur. We could identify sizes and locations of<br \/>\nthe osteophytes to be resected before the surgery.\u201d<\/em><br \/>\n<strong>Dr. S. Kishida, Chiba University, Japan<\/strong><\/p>\n<\/div>\n<div class=\"ui segment\">\n<p><em>\u201cWith 2-Dimensional templating software, it is not easy to select a suitable size and position of<br \/>\nimplants.<br \/>\n3-Dimensional templating software; ZedHip is very informative with 3-Dimensional parameters such as cup<br \/>\nanteversion, inclination, bone quality of acetabulumn and its location to be placed, stem model and size to best<br \/>\nfit in femoral canal, leg length change, etc.<br \/>\nIt brings excellent outcomes to my patients.\u201d<\/em><br \/>\n<strong>Dr. Ryu, Nihon University Hospital, Japan<\/strong><\/p>\n<\/div>\n<div class=\"ui segment\">\n<p><em>\u201cPre-operative planning by ZedHip is very useful to check and confirm acetabular coverage ratio and stem<br \/>\nentry location, etc. during surgery.\u201d<\/em><br \/>\n<strong>Dr. Hoshino, Komaki City Hospital, Japan<\/strong><\/p>\n<\/div>\n<h1>Media<\/h1>\n<p><a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/12\/ZedHip-3D-eng.pdf\">ZedHip 3D-eng<\/a><br \/>\n<a href=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/12\/Post-Op-Assessment.pdf\">Post Op Assessment<\/a><\/p>\n<h1>FAQ<\/h1>\n<h3>System Requirements<\/h3>\r\n<table class=\"ui definition table\">\r\n<tbody>\r\n    <tr>\r\n        <td width=\"20%\">OS<\/td>\r\n        <td>Windows 10 version 1809 or later<\/td>\r\n    <\/tr>\r\n    <tr>\r\n        <td>CPU<\/td>\r\n        <td>Intel Core i5-4670, i7-4770 or higher<br\/>(CPU clock\r\n        rated 3GHz, quad core or higher recommended)<\/td>\r\n    <\/tr>\r\n    <tr>\r\n        <td>RAM<\/td>\r\n        <td>16 GB memory<\/td>\r\n    <\/tr>\r\n    <tr>\r\n        <td>Disk Space<\/td>\r\n        <td>10 GB or more for program installation, 1TB or more for project data storage<\/td>\r\n    <\/tr>\r\n    <tr>\r\n        <td>Monitor Resolution<\/td>\r\n        <td>1920*1080<\/td>\r\n    <\/tr>\r\n    <tr>\r\n        <td>Graphic board<\/td>\r\n        <td>NVIDIA Quadro P3200 or NVIDIA GeForce GTX\r\n        1060 or higher<br\/>(with 3GB or more video memory is\r\n        recommended)<\/td>\r\n    <\/tr>\r\n    <tr>\r\n    <td>Communication Port<\/td>\r\n    <td>1947<\/td>\r\n    <\/tr>\r\n    <\/tbody>\r\n<\/table>\r\n\r\n<ul>\r\n<li>ZedView uses Sentinel HASP (SafeNet\/Gemalto), to provide software license keys for all ZedView modules. The Sentinel HASP driver uses communications port 1947 on your computer.<\/li>\r\n<\/ul>\r\n\n<h3>Conditions for CT image<\/h3>\n<table class=\"ui definition table\">\n<tbody>\n    <tr>\n        <td width=\"20%\">Range<\/td>\n        <td>From femoral head to ankle<\/td>\n    <\/tr>\n    <tr>\n        <td>Data format<\/td>\n        <td>DICOM<\/td>\n    <\/tr>\n    <tr>\n        <td>Slice direction<\/td>\n        <td>Axial<\/td>\n    <\/tr>\n    <tr>\n        <td>Slice pitch<\/td>\n        <td>2mm or less (recommended)<\/td>\n    <\/tr>\n    <tr>\n        <td>FOV<\/td>\n        <td>Value for the entire lower limb<\/td>\n    <\/tr>\n    <tr>\n        <td>Gantry Tilt<\/td>\n        <td>0 degree<\/td>\n    <\/tr>\n    <\/tbody>\n<\/table>\n<h3>Installation cost<\/h3>\n<p>Please contact us for details.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview ZedHip creates 3D models of the bone using CT data, and supports planning and assessing THA (Total Hi [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":123,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_locale":"en_US","_original_post":"20","footnotes":""},"class_list":{"0":"post-127","1":"page","2":"type-page","3":"status-publish","5":"en-US","6":"czr-hentry"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/127","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/comments?post=127"}],"version-history":[{"count":35,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/127\/revisions"}],"predecessor-version":[{"id":2611,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/127\/revisions\/2611"}],"up":[{"embeddable":true,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/123"}],"wp:attachment":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/media?parent=127"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}