{"id":2112,"date":"2021-07-30T08:18:16","date_gmt":"2021-07-29T23:18:16","guid":{"rendered":"https:\/\/www.lexi.co.jp\/?page_id=2112"},"modified":"2021-09-15T17:18:18","modified_gmt":"2021-09-15T08:18:18","slug":"zedview2-5d","status":"publish","type":"page","link":"http:\/\/www.lexi.co.jp\/en\/products\/zedview\/zedview2-5d","title":{"rendered":"ZedView2.5D (Hip\/Knee\/Trauma)"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2381 size-full\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/ZedView_2.5D_en.png\" alt=\"\" width=\"1640\" height=\"664\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/ZedView_2.5D_en.png 1640w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/ZedView_2.5D_en-768x311.png 768w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/09\/ZedView_2.5D_en-1536x622.png 1536w\" sizes=\"auto, (max-width: 1640px) 100vw, 1640px\" \/><\/p>\n            <div class=\"ui modal\">\r\n                <div class=\"header\">\r\n                    Notice\r\n                <\/div>\r\n                <div class=\"content\">\r\n                    <div class=\"description\">\r\n                        <p>\r\n                            The pages you are about to visit include information on a \"professional use only\" medical device.  It is not intended for general distribution.  Are you a medical professional?\r\n                        <\/p>\r\n                    <\/div>\r\n                <\/div>\r\n                <div class=\"actions\">\r\n                    <div class=\"ui black deny button\">\r\n                        No\r\n                    <\/div>\r\n                    <div class=\"ui positive right labeled icon button\">\r\n                        Yes\r\n                        <i class=\"checkmark icon\"><\/i>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n\r\n            <script type=\"text\/javascript\">\r\n                jQuery(function ($) {\r\n                    var dlg = $('.ui.modal')\r\n                        .modal('setting', {\r\n                                closable: false,\r\n                                onApprove: function() {\r\n                                    $.cookie('medical_warn_checked', 'true', { expires: 30, path: '\/' });\r\n                                    return true;\r\n                                },\r\n                                onDeny: function() {\r\n                                    location.href=\"\/en\/\";\r\n                                    return true;\r\n                                }\r\n                            }\r\n                        );\r\n                    if($.cookie('medical_warn_checked') === undefined)\r\n                    {\r\n                        dlg.modal('show');\r\n                    }\r\n                });\r\n            <\/script>\n<h1>Overview<\/h1>\n<p>Zed View 2.5D (Hip, Knee &amp; Trauma) is software that overlays 3D model on X-ray image for supporting THA, TKA and UKA templating and trauma treatment templating.<br \/>\nImplants are displayed on X-ray image, and the size and position can be adjusted. Furthermore, the implants can be rotated and translated 3-dimensionally.<\/p>\n<p>For hip templating, impingement simulation between acetabural and femoral components can be calculated.<br \/>\nFor knee templating, planning in coronal plane and sagittal plane are available.<\/p>\n<h1>Features<\/h1>\n<h2>Database of Patient Records<\/h2>\n<p>User can import CR data in DICOM format into a database application.<br \/>\nPatient information (such as name, sex, date of birth, etc.) can be managed uniformly.<br \/>\nFurthermore, this database application can be used as simple DICOM viewer to view the images.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1999\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h03_55.png\" alt=\"\" width=\"765\" height=\"410\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h03_55.png 1917w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h03_55-768x411.png 768w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h03_55-1536x823.png 1536w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><\/p>\n<h2>Calibration<\/h2>\n<p>At the start of templating, calibration can be done by marking sphere or scale tool positioned close to templating area in X-ray image.<\/p>\n<p>This operation achieves optimal results on magnification and corrects the scale of the image during templating in 2D.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-2000\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h31_06.png\" alt=\"\" width=\"765\" height=\"406\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h31_06.png 1918w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h31_06-768x408.png 768w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h31_06-1536x815.png 1536w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><\/p>\n<h2>Positioning of Implants<\/h2>\n<p>Implants can be placed at optimal positions on 3D model on CR image in a few steps.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-2001\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h49_29.png\" alt=\"\" width=\"764\" height=\"405\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h49_29.png 1452w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h49_29-768x407.png 768w\" sizes=\"auto, (max-width: 764px) 100vw, 764px\" \/><\/p>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-2002\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h50_20.png\" alt=\"\" width=\"765\" height=\"406\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h50_20.png 1916w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h50_20-768x408.png 768w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h50_20-1536x815.png 1536w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-2056\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-14_19h19_47-2.png\" alt=\"\" width=\"766\" height=\"411\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-14_19h19_47-2.png 1876w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-14_19h19_47-2-768x412.png 768w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-14_19h19_47-2-1536x824.png 1536w\" sizes=\"auto, (max-width: 766px) 100vw, 766px\" \/><\/p>\n<h2>Calculation of Parameters<\/h2>\n<p>The change in alignment before and after repositioning is automatically calculated, and the bone resection position, bone cut amount, and implant positioning angle can be visually and quantitatively confirmed.<\/p>\n<h2>ROM Simulation (for Hip)<\/h2>\n<p>During ROM (Range Of Motion) simulation, the position of impingement between components can be checked in 3D, and a red mark is displayed at the point of impingement.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-2004\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h56_36.png\" alt=\"\" width=\"765\" height=\"407\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h56_36.png 1918w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h56_36-768x409.png 768w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_15h56_36-1536x818.png 1536w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><\/p>\n<h2>Repositioning Simulation<\/h2>\n<p>Placed components can be displayed in repositioned status.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-2005\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_16h02_47.png\" alt=\"\" width=\"765\" height=\"506\" srcset=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_16h02_47.png 1232w, http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2021\/05\/2021-05-21_16h02_47-768x508.png 768w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><\/p>\n<h1>Brochure<\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1190\" src=\"http:\/\/www.lexi.co.jp\/wp-content\/uploads\/2018\/10\/123.png\" alt=\"\" width=\"185\" height=\"285\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview Zed View 2.5D (Hip, Knee &amp; Trauma) is software that overlays 3D model on X-ray image for supporti [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":123,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_locale":"en_US","_original_post":"1163","footnotes":""},"class_list":{"0":"post-2112","1":"page","2":"type-page","3":"status-publish","5":"en-US","6":"czr-hentry"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/2112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/comments?post=2112"}],"version-history":[{"count":5,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/2112\/revisions"}],"predecessor-version":[{"id":2392,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/2112\/revisions\/2392"}],"up":[{"embeddable":true,"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/pages\/123"}],"wp:attachment":[{"href":"http:\/\/www.lexi.co.jp\/wp-json\/wp\/v2\/media?parent=2112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}